Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Braz. j. biol ; 842024.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469378

RESUMO

Abstract Particulate matter (PM) is a major air pollutant causing serious health problems. The aim of the present study was to find out concentration of PM in ambient air and its associated health risk in Haripur city, Pakistan. Twenty-three samples were taken at various educational institutes, hospitals, recreational areas and industries in Haripur city. Concentration of PM2.5 (µg/m3) and PM10 (µg/m3) was measured with Youngteng YT-HPC 3000A portable PM counter. The results revealed that values of both PM2.5 and PM10 were above the permissible limits (35 µg/m3 for PM2.5 and 150 µg/m3 for PM10) set by Environmental Protection Agency Pakistan (Pak-EPA) in all the educational institutes, hospitals, recreational areas and industries investigated. Furthermore, significant (p 0.05) variation was found in the concentration of both PM2.5 and PM10 in all the educational institutes, hospitals, recreational areas, and industries studied. The concentration of PM2.5 was positively correlated with the concentration of PM10 in all the sampling sites. Therefore, from 1-14 scale standard of health index, the values of PM2.5 and PM10 exhibited that the ambient air quality of Haripur city Pakistan is under high risk. If the regulatory authorities such as Environmental Protection Agency, Health Department and Local Government monitor PM pollution in different settings of Haripur city, then a decrease can be possible in the pollution level. The remedies that can be taken to overcome the problem of ambient air pollution such as PM are plantation of trees at the sites where there are higher levels of air pollutants and use of masks on personal protection basis along with implementation of pollution control system in industries of Hattar Industrial Estate Haripur city, Pakistan.


Resumo O material particulado (MP) é um importante poluente do ar que causa sérios problemas de saúde. O objetivo do presente estudo foi descobrir a concentração de MP no ar ambiente e sua associação com o risco à saúde na cidade de Haripur, Paquistão. Vinte e três amostras foram coletadas em várias instituições de ensino, hospitais, áreas recreativas e indústrias na cidade de Haripur. A concentração de MP2,5 (µg/m3) e MP10 (µg/m3) foi medida por meio do contador de MP portátil Youngteng YT-HPC 3000A. Os resultados revelaram que os valores de MP2,5 e MP10 estavam acima dos limites permitidos (35 µg/m3 para MP2,5 e 150 µg/m3 para MP10) estabelecidos pela Agência de Proteção Ambiental do Paquistão (Pak-EPA) em todas as instituições de ensino, hospitais, áreas recreativas e indústrias investigadas. Além disso, foi encontrada variação significativa (p 0,05) na concentração de MP2,5 e MP10 em todos os locais estudados. A concentração de MP2,5 correlacionou-se positivamente com a concentração de MP10 em todos os locais de amostragem. Portanto, a partir da escala padrão 1-14 do índice de saúde, os valores de MP2,5 e MP10 mostraram que a qualidade do ar ambiente na cidade de Haripur, Paquistão, está sob alto risco. Se as autoridades reguladoras, como a Pak-EPA, o Departamento de Saúde e o governo local, monitorarem a poluição por MP em diferentes configurações da cidade de Haripur, pode ser que haja uma diminuição no nível de poluição. As medidas que podem ser tomadas para superar o problema da poluição do ar ambiente, como o MP, são o plantio de árvores nos locais onde há maiores níveis de poluentes atmosféricos, o uso de máscaras e a implantação de sistema de controle de poluição nas propriedades industriais de Hattar, na cidade Haripur, Paquistão.

2.
Braz. j. biol ; 84: e256190, 2024. tab, graf, mapas
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1364523

RESUMO

Particulate matter (PM) is a major air pollutant causing serious health problems. The aim of the present study was to find out concentration of PM in ambient air and its associated health risk in Haripur city, Pakistan. Twenty-three samples were taken at various educational institutes, hospitals, recreational areas and industries in Haripur city. Concentration of PM2.5 (µg/m3) and PM10 (µg/m3) was measured with Youngteng YT-HPC 3000A portable PM counter. The results revealed that values of both PM2.5 and PM10 were above the permissible limits (35 µg/m3 for PM2.5 and 150 µg/m3 for PM10) set by Environmental Protection Agency Pakistan (Pak-EPA) in all the educational institutes, hospitals, recreational areas and industries investigated. Furthermore, significant (p<0.05) variation was found in the concentration of both PM2.5 and PM10 in all the educational institutes, hospitals, recreational areas, and industries studied. The concentration of PM2.5 was positively correlated with the concentration of PM10 in all the sampling sites. Therefore, from 1-14 scale standard of health index, the values of PM2.5 and PM10 exhibited that the ambient air quality of Haripur city Pakistan is under high risk. If the regulatory authorities such as Environmental Protection Agency, Health Department and Local Government monitor PM pollution in different settings of Haripur city, then a decrease can be possible in the pollution level. The remedies that can be taken to overcome the problem of ambient air pollution such as PM are plantation of trees at the sites where there are higher levels of air pollutants and use of masks on personal protection basis along with implementation of pollution control system in industries of Hattar Industrial Estate Haripur city, Pakistan.


O material particulado (MP) é um importante poluente do ar que causa sérios problemas de saúde. O objetivo do presente estudo foi descobrir a concentração de MP no ar ambiente e sua associação com o risco à saúde na cidade de Haripur, Paquistão. Vinte e três amostras foram coletadas em várias instituições de ensino, hospitais, áreas recreativas e indústrias na cidade de Haripur. A concentração de MP2,5 (µg/m3) e MP10 (µg/m3) foi medida por meio do contador de MP portátil Youngteng YT-HPC 3000A. Os resultados revelaram que os valores de MP2,5 e MP10 estavam acima dos limites permitidos (35 µg/m3 para MP2,5 e 150 µg/m3 para MP10) estabelecidos pela Agência de Proteção Ambiental do Paquistão (Pak-EPA) em todas as instituições de ensino, hospitais, áreas recreativas e indústrias investigadas. Além disso, foi encontrada variação significativa (p < 0,05) na concentração de MP2,5 e MP10 em todos os locais estudados. A concentração de MP2,5 correlacionou-se positivamente com a concentração de MP10 em todos os locais de amostragem. Portanto, a partir da escala padrão 1-14 do índice de saúde, os valores de MP2,5 e MP10 mostraram que a qualidade do ar ambiente na cidade de Haripur, Paquistão, está sob alto risco. Se as autoridades reguladoras, como a Pak-EPA, o Departamento de Saúde e o governo local, monitorarem a poluição por MP em diferentes configurações da cidade de Haripur, pode ser que haja uma diminuição no nível de poluição. As medidas que podem ser tomadas para superar o problema da poluição do ar ambiente, como o MP, são o plantio de árvores nos locais onde há maiores níveis de poluentes atmosféricos, o uso de máscaras e a implantação de sistema de controle de poluição nas propriedades industriais de Hattar, na cidade Haripur, Paquistão.


Assuntos
Risco à Saúde Humana , Poluentes Atmosféricos , Poluição do Ar , Material Particulado , Paquistão
3.
Braz J Biol ; 84: e256190, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35239789

RESUMO

Particulate matter (PM) is a major air pollutant causing serious health problems. The aim of the present study was to find out concentration of PM in ambient air and its associated health risk in Haripur city, Pakistan. Twenty-three samples were taken at various educational institutes, hospitals, recreational areas and industries in Haripur city. Concentration of PM2.5 (µg/m3) and PM10 (µg/m3) was measured with Youngteng YT-HPC 3000A portable PM counter. The results revealed that values of both PM2.5 and PM10 were above the permissible limits (35 µg/m3 for PM2.5 and 150 µg/m3 for PM10) set by Environmental Protection Agency Pakistan (Pak-EPA) in all the educational institutes, hospitals, recreational areas and industries investigated. Furthermore, significant (p<0.05) variation was found in the concentration of both PM2.5 and PM10 in all the educational institutes, hospitals, recreational areas, and industries studied. The concentration of PM2.5 was positively correlated with the concentration of PM10 in all the sampling sites. Therefore, from 1-14 scale standard of health index, the values of PM2.5 and PM10 exhibited that the ambient air quality of Haripur city Pakistan is under high risk. If the regulatory authorities such as Environmental Protection Agency, Health Department and Local Government monitor PM pollution in different settings of Haripur city, then a decrease can be possible in the pollution level. The remedies that can be taken to overcome the problem of ambient air pollution such as PM are plantation of trees at the sites where there are higher levels of air pollutants and use of masks on personal protection basis along with implementation of pollution control system in industries of Hattar Industrial Estate Haripur city, Pakistan.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Material Particulado/análise , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Poluição do Ar/estatística & dados numéricos , Monitoramento Ambiental/métodos , Paquistão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA